Fetal Doppler for Sale

The portable fetal heart monitor is a handheld fetal heart monitor designed for pregnant women to perform daily fetal heart rate monitoring by themselves. Pregnant women can listen to the fetal heart sounds and calculate the fetal heart rate by themselves to achieve the purpose of pre-pregnancy monitoring and fetal care.


It is mainly suitable for pregnant women who are more than 12 weeks pregnant, especially those who have a history of adverse pregnancy and childbirth, have a high risk of fetal developmental abnormalities, or are more concerned about the health of the fetus. It can help pregnant women monitor the fetal heart rate at home, understand the health of the fetus in time, and increase the sense of security during pregnancy. However, for some pregnant women with severe pregnancy complications or who are considered by doctors to be unsuitable for self-monitoring, they should follow the doctor's advice and use it with caution or avoid it.


Get A Quote

Specifications of Fetal Doppler


Baby Sound A

DesignDouble Headphone Jacks.
MaterialPlastic
Power SupplyTwo 1.5V Batteries.(Aaa Lro3)
Dimension110 Mm(L) *55 Mm(W) *16.8 Mm(H)
WeightAbout 80 G (Including Batteries)


Baby Sound C1

Working ModeReal-Time Fhr Display Mode
Averaged Fhr Display Mode
Manual Mode.
Power SupplyTwo 1.5V Batteries.(Aa Lr6)
Optional Probes2Mhz/3Mhz/8Mhz Probe.
Accuracy± 2 Bpm
Power SupplyTwo 1.5V Batteries (Type: Aa Lr6)
Dimension135 Mm(L)*92 Mm(W)*29 Mm(H)
WeightAbout 245 G (With Battery)


JC10A

Display1.77" Lcd Screen
Fhr Measurement And Display Range50 Bpm ~ 240 Bpm (Bpm Beats Per Minute)
Resolution1 Bpm
Accuracy± 2 Bpm
Rated Working VoltageDc3 V
Battery TypeTwo 1.5V Batteries (Aa Lr6)
Probe
Nominal Frequency3.0 Mhz
Working Frequency3.0 Mhz ± 10%
Negative Peak Sound PressureP_ < 1 Mpa
Output Beam IntensityIob < 20 mW/cm²
Spatial-Peak Temporal-Average Derived IntensityIspta < 100 mW/cm²
Ultrasonic Output PowerP < 20 MW
Working ModeContinuous Wave Doppler
Effective Radiating Area Of Transducer≤ 208 Mm²


JC10A(Led)

Fetal Heart Rate Resolution1 Bpm
Precision Accuracy+2 Bpm
Working ModeContinuous Wave Doppler
DisplayLed Display
Nominal Frequency3.0 Mhz
Working Frequency3.0 Mhz ± 10%
Battery TypeTwo 1.5V Batteries (Aalr6)
Dimension151 Mm(L) X 96 Mm(W) X 33 Mm(H)
WeightAbout 207 G(Including Batteries)


JC10B

Safety ClassificationInternally Powered Equipment, Type Cf Applied Part
Display1.77" Lcd Screen
Fhr Measurement And Display Range50 Bpm ~ 240 Bpm (Bpm Beats Per Minute)
Resolution1 Bpm
Accuracy± 2 Bpm
Rated Working VoltageDc3 V
Battery TypeTwo 1.5V Batteries (Aa Lr6)
Nominal Frequency2.0 Mhz
Working Frequency2.0 Mhz ± 10%
Negative Peak Sound PressureP_ < 1 Mpa
Output Beam IntensityIob < 20 mW/cm²
Spatial-Peak Temporal-Average Derived IntensityIspta < 100 mW/cm²
Ultrasonic Output PowerP < 20 MW
Working ModeContinuous Wave Doppler
Effective Radiating Area Of Transducer≤ 208 Mm²


JC10C

Fetal Heart Rate Resolution1 Bpm
Precision Accuracy+2 Bpm
Working ModeContinuous Wave Doppler
Nominal Frequency3.0 Mhz
Working Frequency3.0 Mhz ± 10%
Battery TypeTwo 1.5V Batteries (Aalr6)
Dimension151 Mm(L) X 96 Mm(W) X 33 Mm(H)
WeightAbout 207 G(Including Batteries)


JC10D

Fetal Heart Rate Range50BPM-240BPM(BPM BEATS PER MINUTE)
Fetal Heart Rate Resolution1BPM
Working ModePulsed ultrasonic Doppler
Precision Frequency2.5MHz
Precision士2BPM
DisplayLED display
Operating Frequency2.5MHz±10%
Peak Negative Sound Pressurep≤l MPa
Power Supply3.7V rechargeable lithium battery


JC10E

Safety classificationinternally powered equipment, type CF applied part
DisplayLED screen
FHR measurement and display range50 BPM ~ 240 BPM (BPM beats per minute)
Resolution1 BPM
Accuracy± 2 BPM
Rated working voltageDC3 V
Battery typeTwo 1.5V batteries (AA LR6)
Degree of protectionagainstingress of liquidIP22
Nominal Frequency2.5 MHz
Working Frequency2.5 MHz ± 1096
Negative Peak Sound Pressurep_ < 1 MPa
Output Beam Intensitybb < 20 mW/cm
Spatial-peak Temporal.average Derived Intensityhota < 100mW/cm
Ultrasonic Output PowerP < 20 mW
Working ModePulse wave Doppler
Effective Radiating Area of Transducer490 M㎡± 1596


JC10F

Safety classificationinternally powered equipment, type CF applied part
DisplayLED screen
FHR measurement and display range50 BPM ~ 240 BPM (BPM beats per minute)
Resolution1 BPM
Accuracy± 2 BPM
Rated working voltageDC3 V
Battery typeTwo 1.5V batteries (AA LR6)
Degree ofprotection against ingress ofliquidIP22robe
Nominal Frequency2.5 MHz
Working Frequency2.5 MHz ± 10%
Negative Peak Sound Pressurep_< 1 MPa
Output Beam Intensitybb < 20 mW/cm
Spatial-peak Temporal-average
Derived Intensitylpta < 100mW/cm²
Ultrasonic Output PowerP < 20 mW
Working ModePulse wave Doppler
Effective Radiating Area of Transducer490 M㎡± 15%


Features of Fetal Doppler
01
Features

Exquisite and compact design, easy to carry: suitable for use at home, travel or out, monitor fetal heartbeat anytime and anywhere.


Unique dual headphone jack design: Let the expectant father and expectant mother participate together to enhance parent-child interaction and emotional connection.


High-sensitivity Doppler probe: The high-sensitivity probe can quickly and accurately capture the fetal heartbeat.


Low ultrasound output intensity, high safety quality: ensure the safety of the fetus and pregnant women, non-invasive and painless, and can be used with confidence.


Low power consumption design: Long battery life, reducing the trouble of frequent battery replacement, suitable for long-term use.


Features

Fetal Heart Rate Monitor Operation Steps

Fetal Heart Rate Monitor Operation Steps


1. Preparation

Check the power of the device to ensure that it is fully charged.

Prepare coupling agent (such as medical ultrasound gel).


2. Pregnant position

Pregnant women lie flat or half-lying, relax their abdomen and expose their lower abdomen.


3. Apply coupling agent

Apply an appropriate amount of coupling agent on the probe surface.


4. Find the fetal heart

Place the probe gently on the lower abdomen (above the pubic bone) and move slowly to find the fetal heartbeat.

After hearing the "dong dong" sound, observe the fetal heart rate displayed on the screen (normal range: 110-160 beats/minute).


5. End of use

Record data.

Turn off the device and clean the probe.


Notes

Use for no more than 10 minutes each time.

If you cannot find the fetal heart rate, try again later or adjust the position.

If you find any abnormalities (such as a high or low heart rate), seek medical attention immediately.



Fetal Doppler Applicable Population


  • Pregnant women

Ordinary pregnant women: Used to monitor fetal heartbeat at home to increase peace of mind.

Pregnant women with high-risk pregnancy: Pregnant women with pregnancy-induced hypertension, diabetes or multiple pregnancies need to monitor fetal health more frequently.

Pregnant women with a history of miscarriage or premature birth: Help monitor whether the fetus is developing healthily.


  • Family members

Family members of pregnant women (such as spouses or other relatives) can use the device to interact with the fetus and enhance parent-child bonding.