The BC300 semi-automatic biochemical analyzer for veterinary use is an intelligent testing device designed for animal medical treatment. It can accurately analyze biochemical indicators in blood and body fluid samples, assist veterinarians in diagnosing diseases, evaluating organ functions, and optimizing treatment plans. The device is based on the Linux operating system, equipped with a touch screen and function key dual operation mode, and supports external USB mouse and keyboard, which is convenient and efficient to operate.
BC300 provides a variety of measurement methods (end point method, two-point method, rate method, dual wavelength method, etc.) and calculation modes (factor method, linear regression, broken line regression, etc.) to meet different testing needs. Its intelligent quality control system supports dual batch quality control settings, automatically generates quality control curves, and can store one year of quality control data and charts to ensure that the test results are accurate and reliable. In addition, the equipment has a power-on self-test function, real-time monitoring of the operating status of the optical path, liquid path and mechanical components, and automatic alarms in abnormal situations to ensure detection stability.
The equipment adopts a light source energy-saving design to extend its service life, and is equipped with a power-off protection function to avoid data loss. It supports four languages: Chinese, English, Spanish and Portuguese, and is suitable for a variety of usage environments. Providing multiple printing methods and Chinese report formats to facilitate data management. BC300 is an ideal choice for animal hospitals, laboratories and scientific research institutions with its high efficiency, accuracy and stable performance.
| BC300 Semi-auto Biochemistry Analyzer | |
| Absorbency range | -0.3~3.0Abs |
| Resolution | 0.001 Abs(display), 0.0001 Abs(internal calculation) |
| Light souce | Halogen lamp(6V 10W, 2000h) |
| Wavelength | 340, 405, 510, 546, 578, 620 nm and 2 free positions |
| Stability | ≤0.005A/30min |
| Temperature control | 25°C, 30°C, 37°C, room temperature |
| Temperature accuracy | 士0.1°C |
| Flow cell | 30 uL |
| Sample Volume | 300-6000ul |
| Cross contamination | <1.0% |
| Memory | results 500 test items, 10000 test |
| Interface | standard RS232, 4 USB, Ethernet interface |
| Display | 7" color LCD |
| Built-in thermal printer or connect external printer | |
Accurate detection: By analyzing blood and other body fluids to measure biochemical indicators, assist in disease diagnosis, organ function assessment and treatment plan formulation.
Intelligent energy saving: The light source automatic switch energy-saving design is adopted to maximize the life of the light source and reduce maintenance costs.
Data security: It has a power-off protection function, automatically saves the measurement results, and avoids the loss of detection data.
Multi-language support: It supports four languages, Chinese, English, Spanish and Portuguese, to meet the needs of users in different regions.
Self-test alarm: automatically detect the operating status of the optical path, liquid path and mechanical components when turned on, and alarm in time when abnormalities occur to ensure detection stability.
Flexible operation: based on the Linux system, supports touch screen and function key dual operation modes, and can be connected to an external USB mouse and keyboard to improve operation convenience.
Multiple measurement methods: provide measurement methods such as endpoint method, two-point method, rate method, dual wavelength method, as well as calculation methods such as factor method, linear regression, and broken line regression to meet diverse detection needs.
Intelligent quality control: Two batch quality control can be set for each project, quality control curves can be automatically generated, one year of quality control data and charts can be stored, query and printing can be supported, and the accuracy of detection can be ensured.
Diversified reports: A variety of printing methods and Chinese report formats are provided to facilitate data management and clinical analysis.
Stable and reliable: Designed specifically for veterinary clinics, with stable performance, it is suitable for animal hospitals, laboratories and scientific research institutions.


Power-on preparation
Connect the power supply and turn on the instrument
Wait for the system self-test to complete (automatically detect the optical path, liquid path, etc.)
Sample preparation
Collect animal blood/body fluid samples and centrifuge them
Put the samples in order in the sample rack
Reagent preparation
Check the reagent expiration date, shake well and put them in the reagent position
Set the reagent batch number and parameters (if necessary)
Test operation
Select the test item (supports endpoint method, rate method, etc.)
Set the sample number and test method
Start the test, and the instrument automatically aspirates samples for analysis
Quality control test (optional)
Insert the quality control product and run the quality control program
Check whether the quality control curve is under control
Result processing
Check the test results, print reports or export data
Abnormal results can be retested for confirmation
Clinical diagnostic applications
Liver function assessment: detection of ALT, AST, ALP, total protein and other indicators
Renal function monitoring: determination of BUN, creatinine, uric acid and other parameters
Pancreatic function test: analysis of amylase and lipase levels
Electrolyte balance: detection of Na+, K+, Cl-, Ca2+ plasma concentrations
Disease screening and monitoring
Diabetes diagnosis: blood sugar detection and glycosylated hemoglobin analysis
Inflammation and infection judgment: C-reactive protein, serum protein electrophoresis
Muscle disease assessment: determination of enzyme activity such as CK and LDH
Abnormal lipid metabolism: cholesterol and triglyceride detection
Want to Get More Details About JCMED Medical Consumables?
We're waiting for your contact!